Technical characteristics
  • BrandArtikul Azia Kabel
  • Country of manufactureUzbekistan
Description

Power cables NYM

NYM - the power cable with a copper conducting vein, with isolation and a cover from polyvinylchloride plastic compound, with filling of space between veins

Scope

The cable is intended for transfer and distribution of electric energy in stationary installations on an alternating voltage to 0,66 kV with a frequency of 50 Hz, including in electroinstallations of buildings and constructions for safe use of electric equipment of a class of protection 1 on electrical safety.
Application of a cable over and in plaster, in dry, damp and wet rooms, and also in a bricklaying and concrete is possible. Laying can be carried out in pipes, in the closed adjusting and curved channels. Besides, laying of a cable on a tree is allowed

Design

Wire brand Description
NYM Vein - the single-wire or multiwire copper conductor
Isolation - polyvinylchloride plastic compound with distinctive coloring according to the European DIN VDE 0250 standard:
Internal cover - termoelastoplast
Cover - polyvinylchloride plastic compound or polyvinylchloride plastic compound of the lowered combustibility

Coloring of conducting veins

black and blue The 3rd vein
greenish-yellow, black and blue
The 4th vein
greenish-yellow, brown, black and blue sections
The 5th vein
greenish-yellow, black, blue, brown, sections

Technical characteristics

Name of characteristics Value of characteristics
Working tension, kV 0,66
Number of veins from 1 to 5
Section of the main veins, mm ² from 1,5 to 50
Section of zero veins, mm ² from 1,5 to 25
Class of conducting veins 1 or 2
Construction length, m not less than 100
Temperature of operation, °C
common industrial execution
executions "нг" - the lowered combustibility
from-50 to +50
from-30 to +50
Resistance of isolation, megohm, not less
for the section of 1,5 mm ²
for sections from 2,5 to 6,0 mm ²
for the sections of 10 mm ² above
10
9
7
The minimum radius of a bend when laying, diameters of a cable 20
Execution regarding fire safety
not extending burning at single laying
not extending burning at group laying (ng):
on the category A F/R
on category ng (And)
on category ng (In)
(without designation)

ng (And F/R)
ng (And)
ng (In)

Cable service life not less than 15 years